What are Mission Critical facilities? Mission Critical facilities must operate 8,760 hours per year without interruption. Because of my background in the Department of Defense (DoD), naturally I tend to think of mission critical facilities as those required by the military in support of the warfighter. Although most data centers are operated for commercial customers, increasingly the Department of Defense is beginning to contract for data center service from commercial suppliers and in many cases, DoD requires that the data center comply with Department of defense security requirements. That said, I will endeavor to include the requirements DoD expects so that your data center can meet those requirements should the need arise.
For many years, NFPA 75 has been the standard of care for fire protection of IT equipment. DoD, GSA and VA design manuals and standards require the provisions of NFPA 75 be adhered to in full, with certain additional provisions. Compliance with NFPA 75 is rarely required by local building or fire codes but is routinely applied to IT equipment facilities on a prescriptive basis. A documented risk assessment is the basis for implementation of the standard for commercial facilities.
Previously, NFPA 75-2013 contained statements that run counter to the 24x7 requirement for data centers such as Section 8.4.2.1, which stated “the power to all electronic equipment shall be disconnected upon activation of a gaseous-agent total flooding system…” The NFPA 75-2017 edition made significant changes to the minimum level of requirements to protect IT equipment from fire and the effects of fire.
Topics covered include:
Site Security
Building Security
Cyber-Security
EMP Protection
Insider Threat

商品描述(中文翻譯)

什麼是任務關鍵設施?任務關鍵設施必須全年無間斷地運作 8,760 小時。由於我在國防部(DoD)的背景,自然我傾向於將任務關鍵設施視為軍方為支持作戰人員所需的設施。儘管大多數數據中心是為商業客戶運營,但國防部越來越多地開始向商業供應商承包數據中心服務,在許多情況下,國防部要求數據中心遵守國防部的安全要求。話雖如此,我將努力包括國防部所期望的要求,以便您的數據中心在需要時能夠滿足這些要求。

多年來,NFPA 75 一直是 IT 設備防火的護理標準。國防部、GSA 和 VA 的設計手冊和標準要求完全遵守 NFPA 75 的條款,並附加某些條款。當地建築或消防法規很少要求遵守 NFPA 75,但通常會以規範的方式應用於 IT 設備設施。已記錄的風險評估是商業設施實施該標準的基礎。

之前的 NFPA 75-2013 版本包含了一些與數據中心 24x7 要求相悖的聲明,例如第 8.4.2.1 節,該節指出「在啟動氣體滅火系統時,所有電子設備的電源應斷開……」NFPA 75-2017 版本對保護 IT 設備免受火災及其影響的最低要求進行了重大更改。

涵蓋的主題包括:
- 現場安全
- 建築安全
- 網絡安全
- EMP 保護
- 內部威脅